LOAD LIMITER

Limitation of the detected load through alarm and pre-alarm levels.

Overload control with double-security system by connecting two units.

Limitation of load (single and sum) for weighing systems up to 4 points, by connecting more units.

Load cell fail alarm.

Set-up and calibration via keyboard and display board removable.

Download usage manual


Zoom Click to enlarge image

Indicator WIN6

Technical Specifications

Power supply12 – 24 V ac ± 15 %
Average consumption4 W
IsolationClass III
Operating temperature-10 / +50 °C (14 / 122 °F) Humidity Maximum 85% non-condensing
Storage temperature-20 / +60°C (-4 / +140°F)
DisplayNumeric 6-digit, 7-segment LED (h 14mm)
Led5 3 mm indicator LEDs of which 3 indicate the relay outputs status
Keyboard4 mechanical keys
Overall dimensions115 mm x 93 mm x 65 mm / 4.53 x 3.66 x 2.56 in (l x h x p)
MountingSupport for DIN rail or OMEGA bar
Case materialPolyamide 6.6 UL 94V-0, self-extinguishing
ConnectionsRemovable screw terminals. Pitch screws terminal blocks 5.08 mm
Load cell input featuresMax 4
Input sensitivity0.02 µV min
Linearity< 0.01% full scale
Temperature deviation< 0.001% full scale / C°
Internal resolution24 bit
Measuring range-3.9 mV/V - +3.9 mV/V
Digital filterfrom 0.1 Hz to 10 Hz selectable
Output rate10 Hz
Number of weight decimalsfrom 0 to 3 decimal digit
Zero / FS CalibrationExecutable through buttons
Cell cable interruption checkAlways present
Analog output in tensionOptional: ± 10 V / ± 5 V
 Resolution16 bits
 CalibrationBy push-buttons
 Impedance≥ 10 kΩ
 Linearity0.03% full scale
 Temperature deviation0.001% full scale / °C
Analog output under currentOptional: 0 - 20 mA / 4 - 20 mA
 Resolution16 bits
 CalibrationBy push-buttons
 Impedance≤ 300 Ω
 Linearity0.03% full scale
 Temperature deviation0.001% full scale / °C
Logical input1 optically isolated dry contact
Logical output alarm2 relay out (24 V DC/AC, one NO contact), 1 relay out (24 V DC/AC, one changeover contact), relay contact capacity 0.5 A
Serial portRs232 / Rs485 (alternatively)
 Max. cable length15m (Rs232) and 1000m (Rs485)
 Baud rateUp to 115 kb/s (default 9600 b/s)
Program code memory32 Kbytes
Data memory2 Kbytes
Conforms to standardsCompliance to EMC norms: EN61000-6-2, EN61000-6-3, Compliance electric safety: EN 61010-1
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

Type6 Pin pull-out terminal block
LengthND
1- Exc. Load cell
2+ Exc. Load cell
3+ Load cell Sense
4 - Load cell Sense
5- Signal load cell
6+ signal load cell
Type18 Pin pull-out terminal block
LengthND
7RS232 Tx
8RS232 Rx
9RS232 GND
10RS485 +
11RS485 -
12Input (Dry contact)
13Input (Dry contact)
14+ ~ (Power supply 12 to 24 Vdc/Vac +/- 15%)
15- ~ (Power supply 12 to 24 Vdc/Vac +/- 15%)
16Analog output + (V or mA)
17Analog output -
18Common Relay Output 1
19N.O. contact Relay Output 1
20Common Relay Output 2
21N.O. contact Relay Output 2
22Common Relay Output 3
23N.O. contact Relay Output 3
24N.C. contact Relay Output 3
Connections  Indicator WIN6

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means